BPBGC - VELCRO FR-127 5 GALLON

  • MSDS: BPBGC
  • Manufacturer: BOSTIK
  • Product Name: VELCRO FR-127 5 GALLON
  • National Stock Number: 8040-00N033426
Product Identification

Product ID:VELCRO FR-127 5 GALLON
MSDS Date:08/01/1986
FSC:8040
NIIN:00N033426
MSDS Number: BPBGC

Responsible Party
BOSTIK
BOSTON STREET
MIDDLETON, MA 01949
US

Emergency Phone: 508-777-0100

Info Phone: 508-777-0100

Preparer: D.C. MOLBERG

Cage: 60775

Contractor
USM CORP SUB OF EMHART INDUSTRIES INC BOSTIK DIV
MIDDLETON, MA 01949 US

Telephone: 508-777-0100

Cage: 70707

Ingredients

CAUSES IRRITATION. CAUSES POSSIBLY IRREVERSIBLE EYE

RTECS: 9999999ZZ


PROD HAS BEEN ASSOCD W/CNS PROBLEMS & KIDNEY & LIVER

RTECS: 9999999ZZ


METHANE, DICHLORO-; (METHYLENE CHLORIDE, DICHLOROMETHANE)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 15.5%

OSHA PEL 500 PPM; 1000, C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON TETRACHLORIDE; (CARBON TET)

CAS: 56-23-5

RTECS: FG4900000

Fraction By Weight: 0.1%

OSHA PEL 10 PPM

ACGIH TLV: S,5PPM/10 STEL,A3 93

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


2-BUTANONE; (METHYL ETHYL KETONE, MEK)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 43.9%

OSHA PEL 200 PPM;300 PPM STEL

ACGIH TLV: 200 PPM;300 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


DGBA EPOXY RESINS; (DIGLYCIDYL ETHER RESIN WITH BISPHENOL

CAS: 25068-38-6

RTECS: SL6475000

Fraction By Weight: 1.2%


TOLUENE; (METHYL BENZENE) (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 15.6%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE CAS# 108-88-3 APPEARS ON THE NAVY LISTING

RTECS: 9999999ZZ


HLTH PROFESSIONALS CONCERNING LATEST HAZARD LIST

RTECS: 9999999ZZ


NO HAZARD KNOWN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL) 50-500 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON/CHLOROFLUOROCARBON (CFC)
MATLS HAVE PRDCED SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.
EPINEPHRINE) MAY BE CONTRAINDICA TED EXCEPT FOR LIFE-SUSTAINING
USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS/CFC'S .
(ING 6)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:GRP 2B
(IARC),ANTICIPATED TO BE A CARCIN (NTP).CARBON TETRACHLORIDE:GRP 2B
(IARC), (SUPP DATA)
Effects of Overexposure:IRRITATION, DIZZINESS, WEAKNESS,
LIGHTHEADEDNESS, HEADACHE, NAUSEA, VOMITING, DIARRHEA.
Medical Cond Aggravated by Exposure:NONE KNOWN TO BOSTIK.

First Aid

First Aid:INGEST:IF SWALLOWED, CALL MD.THE ATTENDING MD MUST DECIDE
WHETHER OR NOT TO INDUCE VOMITING BASED ON HIS EVALUATION OF
PATIENT. INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG GIVE ARTF RESP,
PREF MOUTH TO M OUTH. IF BRTHG IS DIFFICULT GIVE O*2. CALL MD. EYE:
IN CASE OF CONTACT, IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES. CALL MD. SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER.
CALL MD .

Fire Fighting

Flash Point Method:CC
Flash Point:28.0F,-2.2C
Lower Limits:3.78%
Upper Limits:13.3%
Extinguishing Media:WATER SPRAY, FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:SOAK UP LIQUID WITH AN ABSORBENT MATERIAL SUCH
AS SAND, EARTH, SWEEPING COMPOUND OR SOME OTHER ABSORBENT MATERIAL.
PACKAGE ABSORBENT MATERIAL OR SOLID PRODUCT IN STEEL DRUMS WHICH
ARE IN GOOD CONDITIO N. THOROUGHLY CLEAN AREA WHERE SPILL OCCURRED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL LOCATION (60-80F) AWAY
FROM SUNLIGHT & ANY SOURCE OF HEAT, SPKS/FLAME.KEEP CNTNR TIGHTLY
CLSD WHEN NOT BEING USED.USE W/ADEQ VENT.
Other Precautions:AVOID PRLNGD/RPTD BRTHG OF VAPS.AVOID SKIN CONT.USE
IN AREA FREE FROM FLAME & SPKS.NO SMOKING IN AREA OF USE.DO NOT USE
IN GEN VICINITY OF ARC WELDING, OPEN FLAMES/HOT SURFS.HEAT &/UV
RADIATION MAY CA USE FORMATION OF HCL &/PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST IS PREFERRED, MECHANICAL EXHAUST IS
ACCEPTABLE.
Protective Gloves:NITRILE, IMPERVIOUS PLASTIC GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FSHLD .
Other Protective Equipment:SAFETY SHOWER AND EYEBATH.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:MAY INCLUDE CO*2/CO/H*2O VAP, NO*X/WIDE VARIETY OF
INNOCUOUS/TOX FUMES.HYDROGEN CHLORIDE/BROMIDE & CYANIDE WILL ALSO
BE PRDCD ALONG W/SM AMTS OF PHOSGENE.WASTE DISP METH:CLASSIFIED AS
HAZ WASTE UNDER FED REGS IN EFT @ TIME OF PRINTING OF THIS MSDS.
EXPLAN OF CARCIN: ANTICIPATED TO BE A CARCINOGEN (NTP).

Chemical Properties

Boiling Pt:B.P. Text:>104F,>40C
Vapor Pres:126
Vapor Density:2.73
Spec Gravity:0.98
Evaporation Rate & Reference:6.7 (BUTYL ACETATE=1)
Solubility in Water:12%
Appearance and Odor:A STRAW COLORED LIQUID WITH A KETONE ODOR.
Percent Volatiles by Volume:82.8

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, STRONG ACIDS OR ALKALIS, AMINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:UNKNOWN DUE TO COMPLEX NATURE OF MATL.
FUMES FROM COMPLETE/INCOMPLETE COMBUST OF MATL (SUPP DATA)

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W FED, STATE & LOC REGS.BE AWARE
THAT STATE & LOC REQMTS MAY DIFFER WIDELY DEPENDING ON LOCATION &
IN MANY CASES BE DIFFERENT FROM FED RULES. WHEN INTENDING TO
DISPOSE OF MATL, THE USER IS ADVISED THAT PROD WOULD BE (SUPP
DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.